The ATEN Control System, incorporating the VK2100 (ATEN Controller), the VK6000 (ATEN Configurator) and the ATEN Control System App is a standard Ethernet-based management system that connects all hardware devices in a room or large facility to provide centralized control of devices directly and effortlessly via an iPad. The VK2100 works as the main controller that provides great connectivity to all sorts of hardware devices commonly seen in a room. After connecting the hardware, the VK6000 software allows customizable device configuration via creation of a simple system project in 4 easy steps. By connecting to the VK2100 via Ethernet, the ATEN Control System App empowers you with the mobility to control different hardware devices in different rooms whenever and however you like.

Interfaces

Serial
4 x Programmable Bi-directional RS-232/422/485 Port
(4 x DB9 Male Connector, configurable via pin assignments)
- Baud Rate: 300 to 115200 (default: 9600)
- Data Bit: 8 (default) or 7
- Stop Bit: 1 (default) or 2
- Parity: None (default), Even or Odd
- Flow Control: None (default) RTS/CTS
2 x Bi-directional RS-232 Port
(2 x 3-Pole Terminal Block Connector)
- Baud Rate: 300 to 115200 (default: 9600)
- Data Bit: 8 (default) or 7
- Stop Bit: 1 (default) or 2
- Parity: None (default), even or odd

IR/Serial
4 x Programmable IR / Uni-directional RS-232 Port
(2 x 4-Pole Terminal Block Connector)
IR: TTL level (0 to 5 V)
- Carrier Frequency: 10KHz to 455KHz
Serial: Uni-directional RS-232 ( + / - 5 V)
- Baud Rate: 300 to 115200 (default: 9600)
- Data Bit: 8 (default) or 7
- Stop Bit: 1 (default) or 2
- Parity: None (default), Even or Odd

I/O
4 x Programmable Digital Input / Output Channel
(1 x 5-Pole Terminal Block Connector)
Digital Output:
250 mA sink from 12 VDC
Digital Input:
- VDC Mode
Input Voltage Range: 0 to 24 VDC
Programmable Range: 1 to 24 VDC
- Dry Contact Mode
Pull-up 2k ohms to + 12 VDC

Relay
4 x Relay Channel (2 x 4-Pole Terminal Block Connector)
Normally open, isolated Relays
Contact Rating: Max 24 VDC, 2A

VDC
4 x 12 VDC Output Port (2 x 4-Pole Terminal Block Connector)
Power Supply: 12 VDC, 2A Max (shared by 4 ports)

Ethernet
1 x RJ-45 Female, 10/100Base-T
Supported Protocol: ICMP, TCP/IP, DHCP, HTTPS, SSH
DHCP-enabled. The following default IP settings will be used if no IP is assigned within 30 seconds: IP: 192.168.0.60
Subnet Mask: 255.255.255.0
Establishes VK2100 connection with the VK6000 (ATEN Configurator) and iPad (ATEN Control System App)

Switches
Controller ID : 1 x 16-segment Switch
Power : 1 x On/Off Switch

IR Learning
1 x IR Receiver LED

Reset Button
1 x Semi-recessed Pushbutton

USB
1 x USB Type A

Power
Consumption : 40 Watt
Maximum Input Power Rating : Internal Power: 100-240 VAC, 50-60 Hz

Environmental
Operating Temperature : 0 - 50oC
Storage Temperature : -20 - 60oC
Humidity : 0 - 80% RH, Non-Condensing

Housing
Metal

Item Dimension (L inchxW inchxH inch)
22 x 10 x 6

Weight
8.90 lb

Warranty Information
3 Years