Protects Mission-Critical Equipment
??? Provides fully regulated AC output for home/office workstations, media centers and home entertainment systems

??? Audible alarm signals loss of utility power or low battery

??? 8 C13 outlets???2 surge-only

??? C14 inlet accepts user-supplied AC power cord with country-specific plug

??? 455-joule surge suppression rating


Reliable Battery Backup
??? Supports half load up to 10 min.

??? Powers entry-level PC up to 90 min.

??? Internal batteries designed for hot-swap field replacement

??? 95% line-power efficiency rating saves money in energy costs

??? Cold-start capability enables turn-on in battery mode during blackouts


Automatic Voltage Regulation (AVR)
??? Maintains 230V nominal output over input range of 170V???280V without using battery power


EMI/RFI Line Noise Filtering
??? Removes electromagnetic and radio frequency interference that can disrupt or damage equipment???s performance


Interactive LCD Screen
??? Front-panel LCD signals voltage, battery and load statuses

??? Supports multiple advanced user setup and operating preferences

??? Rotates for easy viewing in rack-mount or tower configurations


Communications Port
??? USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert


RJ45 Telephone/Ethernet Protection Jacks
??? Protect phone/DSL/fax/modem/Ethernet network against power surges

OUTPUT
Output Volt Amp Capacity (VA): 1500
Output kVA Capacity (kVA): 1.5
Output Watt Capacity (Watts): 900
Nominal Output Voltage(s) Supported: 220V/ 230V/ 240V
Nominal Voltage Details: 230V nominal output in battery mode
Frequency Compatibility: 50 / 60 Hz
Frequency Compatibility Details: Automatic frequency selection
Output Voltage Regulation (Battery Mode): +/- 5%
Output Receptacles: (8) C13
UPS Output Receptacles (Surge Suppression Only): 6 UPS outlets, 2 surge-only outlets
Hot-Swap PDU options: PDUBHV10 (2U / 8 C13 outlets)
Output AC Waveform (AC Mode): Sine wave
Output AC Waveform (Battery Mode): PWM sine wave

INPUT
Rated input current (Maximum Load): 9A
Nominal Input Voltage(s) Supported: 230V AC
Input Connection Type: C14 inlet
Input Circuit Breakers: 10A fuse
UPS Input Cord Length (ft.): 6
UPS Input Cord Length (m): 1.8
Input Phase: Single-Phase

BATTERY
Half Load Runtime (min.): 10 minutes (450 watts)
DC System Voltage (VDC): 24
Battery Recharge Rate (Included Batteries): Less than 8 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge: RBC51(requires 2)
Expandable Runtime: No

VOLTAGE REGULATION
Voltage Regulation Description: Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V
Overvoltage Correction: Input voltages between 247 and 280 are reduced by 15%
Undervoltage Correction: Input voltages between 170 and 207 are boosted by 18%

USER INTERFACE, ALERTS and CONTROLS
Front Panel LCD Display: LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes
Switches: Power switch offers whole UPS power control, Scroll/mute button enables LCD selection options and silences audible alarm Test button initiates self test
Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm: Audible alarm indicates power-failure and low-battery conditions

SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating: 455
UPS AC Suppression Response Time: Instantaneous
UPS Dataline Suppression: 1 line TEL/DSL (1 in / 1 out), 10/100Base T Ethernet
EMI / RFI AC Noise Suppression: Yes

PHYSICAL
Installation Form Factors Supported with Included Accessories: Tower
Primary Form Factor: Tower

ENVIRONMENTAL
Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity: 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) : 79
Battery Mode BTU / Hr. (Full Load): 918
AC Mode Efficiency Rating (100% Load): 95%

COMMUNICATIONS
Communications Interface: USB (HID enabled)
Network Monitoring Port Description: Supports detailed monitoring of UPS and site power conditions
PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable: USB cabling included
WatchDog Compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER
Transfer Time: 6 milliseconds
Low Voltage Transfer to Battery Power (Setpoint): 170V (factory setting), 175V (medium setting), 180V (narrow setting)
High Voltage Transfer to Battery Power (Setpoint): 280V (factory setting), 275V (medium setting), 270V (narrow setting)

SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
High Availability UPS Features: Hot swappable batteries
Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS

CERTIFICATIONS
UPS Certifications: CE, Tested to GOST (Russia), Tested to SASO (Saudi Arabia)
UPS Certification Details: EN62040-1, EN62040-2 Class A

Item Dimension (L inchxW inchxH inch)
9 x 11 x 20

Weight
27.00 lb

Warranty Information