Focus on Americas Market
View Quotation Cart ( 0 )
SU60K | ActForNet

MPN: SU60K
Category: UPS >> UPS
Vendor: Tripp-Lite
Weight: 1356 LB(S)
Price: US$ 29962.5

-
+
Tripp Lite's SU60K (60kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In an N+1 configuration, the SU60K features three self-contained, redundant 20kVA power modules that can be hot-swapped (with the load powered) if maintenance is required. Connect two SU60K models in parallel (1+1 configuration) to provide fail-safe redundancy (two 60kVA models supporting a 60kVA load) or to increase capacity (two 60kVA models supporting an 120kVA load).


??? N+1 configuration: three self-contained, redundant 20kVA power modules can be hot-swapped (with the load powered) if maintenance is required

??? 1+1 configuration: connect two SU60K models in parallel to provide fail-safe redundancy or to increase capacity

??? High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create low input Total Harmonic Distortion (THDi)

??? Extremely efficient operation (up to 96%) saves money by lowering electricity consumption

??? True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times

??? Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Output
Output Volt Amp Capacity (VA): 60000
Output kVA Capacity (kVA): 60 Output Watt Capacity (Watts): 48000
Output kW Capacity (kW): 48
Power Factor: 0.8
Crest Factor: 3.1
Nominal Output Voltage(s) Supported: 120/208V 3-PH Wye
Frequency Compatibility: 50 / 60 Hz
Output Voltage Regulation (Line Mode) : +/- 1%
Output Voltage Regulation (Battery Mode) : +/- 1%
Output Receptacles: Hardwire
Output AC Waveform (AC Mode) : Sine wave
Output AC Waveform (Battery Mode) : Pure Sine wave

INPUT
Rated input current (Maximum Load) : 125A (per phase, online)
Nominal Input Voltage(s) Supported: 120/208V 3-PH Wye
Nominal Input Voltage Description: 3-Phase Wye, 4 wire (L1, L2, L3, N, G)
UPS Input Connection Type: Hardwire
Input Phase: 3-Phase


BATTERY

Expandable Battery Runtime: Battery set sold separate
External Battery Pack Compatibility: BP480V200, BP480V26B, BP480V300, BP480V400, BP480V40C, BP480V500
Expandable Runtime Description: External battery pack wiring is contractor supplied
DC System Voltage (VDC): +/- 240VDC
Battery Recharge Rate (Included Batteries): Less than 4 hours from 10% to 90%
Battery Replacement Description: Hot-swappable, replaceable batteries
Expandable Runtime: Yes

VOLTAGE REGULATION
Voltage Regulation Description: Online, double-conversion power conditioning
Overvoltage Correction: Maintains continuous operation without using battery power during overvoltages to 150 / 260 (3-Phase, 4-Wire, wye), reducing output within 1% of nominal
Undervoltage Correction: Maintains continuous operation without using battery power during brownout / undervoltage conditions to 94 / 163 (3-Phase, 4-Wire, wye)

USER INTERFACE, ALERTS and CONTROLS
Switches: ON button turns UPSs inverter ON. OFF button turns UPSs inverter OFF. LCD Display Control Buttons browses through and selects items displayed on LCD screen. Emergency Power Off button turns
UPS output OFF and disables Bypass output. Manual Bypass breaker bypasses the UPSs inverter during maintenance.
Alarm Cancel Operation: Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm: Alarms warn against a variety of operational conditions: low-battery, overload, shutdown, bypass and more
LED Indicators: 4-LED Display: Displays normal AC input, on battery power, bypass input and fault conditions

SURGE / NOISE SUPPRESSION
EMI / RFI AC Noise Suppression: Yes
AC Suppression Joule Rating: 4675
AC Suppression Response Time: Instantaneous

Installation Form Factors Supported with Included Accessories
Tower

Primary Form Factor
Tower

Cooling Method
Fans

UPS Housing Material
Steel

ENVIRONMENTAL
Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity: 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load): 13998
Battery Mode BTU / Hr. (Full Load): 14254

COMMUNICATIONS
Communications Interface: DB9 Serial, Slot for SNMP/Web interface
Network Management Cards: SNMPWEBCARD, TLNETCARD, WEBCARDLX, MODBUSCARD
PowerAlert Software: For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable: DB9 cabling included

LINE / BATTERY TRANSFER
Transfer Time: No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during undervoltages as low as 94 / 163V AC (3-Phase, 4-Wire, wye). Below this point, output is maintained utilizing battery reserves.
High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation during overvoltages as high as 150 / 260V AC (3-Phase, 4-Wire, wye). Above this point, output is maintained utilizing battery reserves.

SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
High Availability UPS Features: Automatic inverter bypass Hot swappable batteries
Green Energy-Saving Features: High efficiency economy mode operation Schedulable daily hours of economy mode operation

CERTIFICATIONS
UPS Certifications: Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) ROHS (Restriction of Hazardous Substances)

Package Includes
SU60K UPS System
Serial communications cable
Parallel cable (for 1+1 operation)
Instruction manual and startup checklist
Warranty information

Item Dimension (L inchxW inchxH inch)
16 x 8 x 8

Weight
7.00 lb

Warranty Information
3 Years