MPN: SU5000RT4U
Category: UPS >> UPS
Vendor: Tripp-Lite
Weight: 149.6 LB(S)
Price: US$ 3647.36

-
+
1.5000VA / 5kVA on-line, double-conversion, extended run, 4U all-in-one rack / tower UPS

2. Maintains dual 208/120 or 240/120V output /-3 during brownouts and overvoltages (4 wire split-phase input)


3. Simultaneous use of HID compliant USB port, serial port, SNMP/Web card slot, and EPO interface - front panel LCD digital display for real-time site electrical and detailed UPS operating parameters


4. Detachable plug outlet panel with auto/manual bypass and fault tolerant design enables hot-swap UPS replacement without powering off connected equipment


5. Expandable runtime with optional BP192V12-3U external battery packs


6. USD250,000 Ultimate Lifetime Insurance (USA, Puerto Rico Canada only)


7. Estimated Retail Pricing USD2,900.00

OUTPUT:
Output Volt Amp Capacity (VA) :
5000
Output kVA capacity (kVA) :
5
Output Watt Capacity (watts) :
3800
Output kW capacity:
3.8
Output power factor:
0.8
Crest Factor:
3:1

Nominal Output Voltage(s) Supported:
120V 208V 240V
Nominal Voltage details:
240/120V or 208/120V split phase output
Frequency compatibility:
60 Hz
Output voltage regulation (line mode)+/- 3%
Output voltage regulation (Economy line mode) :
+/- 10%
Output voltage regulation (Battery mode) :
+/- 3%

Built-in UPS output receptacles:
8 5-15/20R outlet(s) 2 L6-20R outlet(s) 2 L6-30R outlet(s)
Output circuit breaker:
20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered
Output AC waveform (AC mode) :
Sine wave
Output AC waveform (battery mode):
Pure Sine wave

INPUT:
Rated input current (at maximum load) :
21A
Nominal Input Voltage(s) Supported:
208V AC / 120V AC (4 wire split single phase) 240V AC /120V AC (4 wire split single phase)
UPS input connection type:
L14-30P
UPS input connection description:
4 wire split-phase input (L1, L2, N, G)
UPS Input cord length (ft.) :
10
UPS Input cord length (m) :
3
Recommended Electrical Service:
30A 208/120V Split Phase
Input cord length (m) :
3

BATTERY:
Full load runtime (minutes) :
6 min. (3800w)
Half load runtime (minutes) :
14 min. (1900w)
Expandable battery runtime:
Supports extended runtime with optional external battery packs
External battery pack compatibility:
BP192V12-3U BP192V557C-1PH BP192V787C-1PH BP192V1037C-1PH BP192V1407C-1PH
DC system voltage (VDC) :
192

Battery recharge rate (included batteries) :
Less than 6 hours from 10% to 80%
Replacement battery cartridge (internal UPS battery replacement) :
RBC9-192
Battery Access:
Front panel battery access door
Battery replacement description:
Hot-swappable, user replaceable batteries

VOLTAGE REGULATION:
Voltage regulation description:
Online, double-conversion power conditioning
Overvoltage correction:
3% output voltage regulation during overvoltages to 140 (measured L1-N : L2-N)
Undervoltage correction:
2% output voltage regulation during undervoltages to 65 (measured L1-N : L2-N)

LEDS ALARMS and SWITCHES:
LED Indicators:
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status LCD screen offers additional information and control options
Alarms:
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation:
Alarm cancel switch
Switches:
Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. Battery Charge level switch allows the charger output to be adjusted to a higher charge rate when additional battery packs are added.

SURGE / NOISE SUPPRESSION:
UPS AC suppression response time:
Instantaneous
EMI / RFI AC noise suppression:
Yes

PHYSICAL
Installation form factors supported with included accessories
4 post 19 inch rackmount (mounting rail kit included)
Installation form factors supported with optional accessories
2 post rackmount (2POSTRMKITWM) Tower (2-9USTAND)
Primary form factor
Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches)
7 x 17.5 x 30.8
Installed whole system total rack space height (rack spaces)
4U
Secondary form factor
Tower (requires 2-9USTAND)
UPS housing material
Steel
Cooling method
Fan

COMMUNICATIONS
Communications interface
USB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interface
Network monitoring port description
RS232 and contact closure communications are supported on one DB9 port
PowerAlert software
Included
Communications cable
USB and DB9 cabling included

SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure)
Cold-start operation supported
High availability UPS features
Automatic inverter bypass Manual bypass switch Detachable hot-swap PDU Hot swappable UPS power module Hot swappable batteries
Green and high efficiency features
High efficiency economy mode operation Schedulable daily hours of economy mode operation

CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI)

Warranty Information
Extended warranties: 3 Year WEXT3-5000, 5 Year WEXT5-5000
On-site warranties: 2 Year WOS2-5000, 3-Year WOS3-5000, 5 Year WOS5-5000
250,000 Ultimate Lifetime Insurance (USA, Puerto Rico and Canada only